Kagaznama

Fire NOC Application

At a glance

Price
Free
Stamp duty
No stamp duty: it creates no right in property, so it is not an instrument under section 2(14), Indian Stamp Act, 1899.
Registration
Not registrable: creates no right in property; section 17, Registration Act, 1908 doesn't apply.
Witnesses
Not required.

Free

Documents are free. Only kits are paid.

Free: up to 5 documents a day.

Guided questions, full draft on screen, download in Word.

See all prices

Also called

  • fire safety certificate application
  • fire approval request
  • building fire NOC

When you need it

Use this for fire-safety clearance at the plan, completion, occupation or renewal stage. Punjab takes Fire NOC applications; Chandigarh routes it through its Fire Branch. State occupant load and hydrant/detection systems, not merely "as per NBC."

Read more

Requirements depend on occupancy and height; approval may need inspection.

Whether you can fill this in here

You can fill this in here

You can fill this one in on this site, and read the whole draft on screen before you decide anything about it. It is a carefully drafted template; it is not advice about your own facts.

Fill this one in
See stamp duty, registration and witnesses

What follows is written for Punjab and Chandigarh. It states the position there rather than describing how it varies, so the amounts below are the ones that apply — worth confirming at the sub-registrar’s office, because rates change. If the property is anywhere else in India, none of this is yours.

Stamp duty

No stamp duty: it creates no right in property, so it is not an instrument under section 2(14), Indian Stamp Act, 1899. Print on plain paper; pay only the authority's fee. Any affidavit filed is stamped separately.

Registration

Not registrable: creates no right in property; section 17, Registration Act, 1908 doesn't apply.

Notarisation

Not required, unless the authority asks for an affidavit.

Witnesses

Not required. The owner's and the professional's signatures suffice.

Request Stamp Paper

Sample preview — placeholder answers, not your data

FIRE NOC APPLICATION

Application date: 1 April 2026

Applicant: Aarav Sharma, Sector 21, Panchkula, capacity Owner/allottee. Phone: 98765 43210; email: aarav@example.com.

Building/site: Plot 118, Sector 66, SAS Nagar, Punjab (Residential plot/building), Plot 118, Sector 66; allotment AL-118., site area 836.13 sq m. Title/allotment: Conveyance deed no. 2345 dated 10 June 2022. Jurisdiction Punjab; authority GMADA / competent building authority.

  1. 1. STAGE AND OCCUPANCY

Application stage: Building-plan fire approval. Building use: Office/business occupancy.. Height: 18 m. Floors: 6. Basements: 1. Total floor area: 5,200 sq m.

Occupant-load status: Occupant load calculated from applicable code/use. Estimated load: 420 persons.

  1. 2. LIFE SAFETY

Means of escape: Two enclosed fire stairs and protected exit corridors.. Fire-tender access: Required access shown and kept unobstructed. Emergency lighting/signage: Emergency lighting and exit signage provided.

  1. 3. FIRE SYSTEMS

Systems: Sprinklers, hydrants, addressable alarm, fire pumps and extinguishers.. Fire-water/pumps: 100 KL fire tank with duty, standby and jockey pumps.. Electrical/HVAC fire safety: Required fire/smoke controls incorporated.

  1. 4. PROFESSIONALS

Architect: Ar. Simran Kaur (CA/2012/55555). Structural engineer: Er. Neeraj Khanna (SE/CHD/2024/118).

  1. 5. DRAWINGS AND INSPECTION

Documents: Fire layout, floor plans, system schematic, pump/tank schedule, building sanction.. Inspection readiness: Ready for inspection. Requested inspection: 2 April 2026

  1. 6. REQUEST

Please scrutinise the fire-safety design/installation and issue the applicable approval or Fire NOC/certificate after the required inspection and testing.

PERSONAL DATA NOTICE

This notice is given under the Digital Personal Data Protection Act, 2023.

Personal data in this document is collected only to prepare, submit and administer the Fire NOC or fire-safety approval application, communicate about that purpose, verify expressly supplied property and approval information, and retain an evidentiary application record.

The record will be held by Kagaznama and may be shared only with the applicant, owner, architect, engineer, licensed professional, project consultant, lender, contractor, competent planning/building/fire/environment/water authority, or other person directly involved in the stated approval.

If the application is withdrawn, refused or does not proceed, personal data will be retained for 90 days and then erased. If it proceeds, the record will be retained for the approval/project plus 12 months, except where a statute or authority record-retention rule requires a longer named period.

A person named here may withdraw consent for future consent-based processing, request correction or erasure when the stated purpose has ended, or raise a grievance by writing to privacy@example.com. The record-holder should acknowledge and respond within 30 days.

Questions about this document

Does the Fire NOC Application need stamp paper or stamp duty in Punjab and Chandigarh?

No stamp duty: it creates no right in property, so it is not an instrument under section 2(14), Indian Stamp Act, 1899.

See the full position on stamp duty, registration and witnesses
Does the Fire NOC Application need registration in Punjab and Chandigarh?

Not registrable: creates no right in property; section 17, Registration Act, 1908 doesn't apply.

See the full position on stamp duty, registration and witnesses
What does the Fire NOC Application cost on Kagaznama?

Free.

Documents are free. Only kits are paid.

Does the Fire NOC Application need witnesses?

Often needed with this document

Back to Land records, title checks and approvals

We've updated our Terms

Please read the updated documents below and accept them once to keep taking documents away and buying kits. Browsing, filling in and previewing a document are not affected.

Fire NOC Application — format | Kagaznama